Support

Answers to common questions, manuals, and software downloads.

Frequently asked questions

How do I download data from a datalogger?

Connect the TMD Adapter to an Android phone or tablet, or to a computer, with a USB-C cable, touch the top of the datalogger (the metal cap) to the adapter, and use the free Lolly software: TOMST Lolly for Android on a phone or tablet, Old Lolly on a Windows computer. Both are on the Software page.

Is there a mobile app?

Yes - TOMST Lolly for Android runs on Android phones and tablets and connects to your dataloggers through the TMD Adapter over USB-C, so you can configure devices and download data in the field without a laptop. It is available on Google Play; the link and details are on the Software page.

Is there an iPhone version?

Not at the moment, and that is down to how iOS works, not to a choice of ours. Reading a datalogger needs direct low-level communication with the TMD Adapter, and iOS does not let apps talk to accessories that way. Supporting iPhone would mean redesigning the adapter itself to meet Apple's hardware program, which would make it more expensive and add parts that can fail - working against the simplicity and reliability the whole system is built for. For fieldwork the practical answer is a rugged Android phone: inexpensive and hard-wearing, and TOMST Lolly for Android does everything you need on site.

Do I need any special equipment?

No. Every TOMST datalogger is completely autonomous: it measures on its own from the day it ships. You only need one TMD Adapter and the free Lolly software to configure devices and download data.

How long does the battery last? Can I replace it?

More than 10 years in the recommended Basic (15-minute) mode - nothing to charge, nothing to switch on. That figure is what our installed devices have shown us, and they keep running past it: dataloggers installed over 12 years ago are still recording, many devices have passed 14 years, and a TMS Standard typically still has a large battery reserve after 15. The cell itself is guaranteed by the battery manufacturer: its chemistry is rated for 10 years (20 on the TMS Extreme and the variants built on it). The units proving this are older hardware: we improve the devices continuously without announcing it, while keeping measurements comparable across generations. The battery is sealed in and not replaceable - that sealed body is what keeps the device watertight in the field. How long a device lasts depends on the mode you set in Lolly and on the temperatures the device sees: see how long a datalogger lasts.

My device is damaged or shows odd data. What should I do?

Email us first, and do not open the device. We recover data from damaged dataloggers free of charge; a repair may be charged, depending on the damage.

I can't download data from my datalogger.

Make sure you have the latest version of Lolly. TOMST Lolly for Android is updated through Google Play. In Old Lolly, open Options and select "Check for update": it updates itself and the TMD Adapter firmware, and the datalogger firmware is updated when the datalogger is connected.

Does Lolly run on macOS?

TOMST Lolly for Mac is coming: the same program as TOMST Lolly for PC, built for macOS (see the software page). Old Lolly is a Windows application; on a Mac it runs in a Windows virtual machine (e.g. Parallels). Until the Mac version is here, the other way is TOMST Lolly for Android on a phone or tablet: it sets up the dataloggers and downloads their data without a computer.

Is there a wireless version?

No, TOMST dataloggers are offline on purpose. Without a radio the battery lasts for years, there is no subscription to pay, and there is no infrastructure to maintain. Data is collected with the TMD Adapter when you visit the site.

How do I convert raw soil moisture values to volumetric soil moisture?

You do not have to. The raw signal is mainly for following change: rain, drying and drought stand out in it as it is, and many studies use it just like that. If you want vol% values, use the Calibration function in Lolly: pick a soil type (or define your own) and the raw signal (~500-3600) is converted to volumetric soil moisture in vol%. Details are in the TMS Calibration Handbook on the Support page; for larger analyses we recommend the myClim R package. A conversion from a pre-set soil type is approximate; your own calibration curve from a soil sample comes closer.

How do I convert Point Dendrometer readings to micrometers?

Multiply the raw digital values by the proportionality constant 8 890 / (34 000 - 1 279) ≈ 0.272 µm per unit.

How do I place an order?

Use the quotation request form or email us directly; we reply with a quotation that includes shipping to your country. We do not require prepayment; payment terms are agreed to fit your needs.

How fast is delivery?

Smaller orders (up to about 10 devices) are usually dispatched within 1-2 days; for larger orders we recommend ordering in advance. We ship with FedEx, so a package usually arrives within a few days of dispatch.

How do I share files with TOMST?

Through the file page: one page for files in both directions, without email size limits. To send us something, choose the file there; it is encrypted the moment it arrives, with a code that only you see, and nobody at TOMST can open it until you pass that code on (by phone, or in a message of its own). When we have a file for you, or are expecting one from you, we send you a link and a code; the link shows what is waiting and until when, and the code opens it. Files are up to 500 MB each, and how long a file stays is set when it is put up.

Why is there no cookie consent banner?

Because nothing on this site is the kind of thing such a banner asks about: no tracking, no advertising, and nothing loaded from anyone else. This is everything it does.

Two small cookies. One holds your country, a rough guess our server makes from your IP address, so a form can start with it filled in and a few pages can show what applies where you are; it lasts a week. The other remembers which regional site you chose, or the one the site first sent you to.

One more, when you pick a language yourself. If you choose a language in the region box at the top of a page, a third cookie remembers it for a year, so the home page opens in that language next time. Only your own choice sets it, never the site.

Counting on our own servers. They count the requests they receive. Your IP address is shortened before anything is written down, and nothing links one visit to the next. To notice a VPN or a proxy, they also note which DNS server asked for the two test addresses described below and how the first packet of each connection is built (which kind of system sent it, and its size); only the conclusion is written down, and the full addresses are forgotten within two minutes.

A few results from the page. While a page is open, your browser works out whether the visit looks like a person, an AI agent or a script, how quickly each of our servers answers you, whether your browser calls the connection a mobile one, and which country your browser's time zone and language point to. Once, it also fetches two test addresses of ours, one that works over IPv4 alone and one over IPv6 alone, so our server can see whether both come from the same place (never from mainland China). Only those results leave your browser, as a few numbers with nothing that identifies you, and nothing of it is stored on your device. Our servers use them to tell people from machines in the statistics, to notice a visit that comes through a VPN or a proxy, and to send each visitor to the server nearest them.

A check before a form is sent. When you send the quotation form, the research list's form or a feedback, our forms service may first give your browser a short piece of arithmetic to do, and your browser sends with it how long the form took, how many keys and touches it saw, whether the browser says it is automated, and the result above. Now and then the service may also ask for a small puzzle or a question, or offer to take your message by e-mail instead; for the puzzle it receives the path the piece took while you dragged it. It all goes to our own forms service and serves that one check; with your message only the outcome is kept, a score and what was asked, never the path.

When you close an announcement, your browser remembers that you closed it, and when the site suggests a regional page that fits you better, it remembers until you close the tab that it already asked. None of this builds a profile of you, and none of it is shared with anyone.

How long a datalogger lasts

A TMS Standard datalogger has memory for 507 872 records; each day one record is used for a timestamp and the rest for readings. How long the memory lasts, and how long the device keeps measuring on its battery, depend on the mode you set in Lolly:

ModeIntervalMemory lasts (TMS Standard)
BasicRecommendedevery 15 minutes14 years 4 months
Meteoevery 10 minutes9 years 7 months
Smart8 times per hour7 years 2 months
Intensiveevery 5 minutes4 years 10 months
Experimentevery minuteabout 352 days
Hourlyevery hour55 years 7 months

Basic mode suits almost every deployment. It keeps the datalogger in its optimal range, and the memory lasts about 14 years - comfortably beyond the 10-plus years expected of the battery.

Measuring less often does not save the battery. The electronics draw a small amount of power even between readings, so Hourly mode does not make a device last meaningfully longer than Basic - it simply records fewer points and downloads faster. Choose it for those reasons, not to extend battery life. Faster modes (Meteo, Smart, Intensive, Experiment) do the opposite: they shorten battery life and fill the memory sooner.

A TMS Standard typically still has a large battery reserve after 15 years in Basic mode. A Point Dendrometer uses the same electronics, which last as long, though its measurement probe is a mechanical part that does not. The TMS Extreme is the exception: its battery reserve is large enough that a slower mode genuinely extends the deployment, so it can keep logging well beyond a decade.

Expected lifespan in Basic mode: more than 10 years. That number comes from watching installed devices in the field, not from a spec sheet, and the devices keep running past it: many are beyond 14 years, and many are still in good condition at around 15. The cell itself is guaranteed by the battery manufacturer: its chemistry is rated for 10 years (20 on the TMS Extreme and the variants built on it), and in practice it usually lasts longer still. Conditions move the figure either way - warmth drains a battery faster, cold slows the discharge.

The devices that prove it are older hardware. The units that have been recording for 12 years and more are earlier generations. Hardware and firmware are improved continuously - usually small internal changes we never announce, which simply appear in the units we ship next. Measurements stay directly comparable across generations, so an old device and a new one belong in the same dataset without any conversion. Put a TMS from five years ago beside one made today and the difference is obvious, most of it inside.

Data cannot be deleted from a datalogger - by design. Erasing would expose the recorded data to human error, and we put reliable data first. In practice a device's end of life usually just means the memory is full, which is one more reason Basic (or Hourly) gets the most out of a single fill.

Experiment mode (a measurement every minute) is meant for short experiments only. It fills the whole memory in about 352 days, and because the device itself has thermal mass, sampling faster than every 15 minutes adds little real information. It is no longer offered in the Lolly Android app.

Data file format

Every download produces a CSV text file named after the serial number and download date, e.g. data_96626360_2026_07_04_7.csv - the serial number is engraved on the top of the device. Where the file lands depends on the platform: see the Software page. Each line is one record with nine semicolon-separated values:

Live sample line: hover over or tap a value

 

Simulated from Prague's typical climate, updating with the real Basic-mode clock - not data from a real device. -200 in a temperature column and 255 in the moisture column mean the reading is not present on that device, or it failed.

Hover or tap any value above to see what that column means. Click to keep it open.

Manuals & downloads

Media & press

The press kit holds the whole range at 3 000 px on the long edge: TMS variants, the Point Dendrometer, the Thermologger, accessories, instruments installed in the field, and both versions of Lolly. Higher-resolution originals on request.

Files to and from TOMST
Files for us, or files we have put up for you. Choose several files or a whole folder: they go as one upload, encrypted with one code. Up to 500 MB per upload.
Send or collect files
Didn't find your answer?
Write to us - the answer comes directly from the people who build the devices.
Email: tomst@tomst.com