Csv output is located in the root of the lolly program in folder DATA. For example in the c:\program files\lolly\DATA There are two csv files produced during each read session: binary and data.
Binary file is memory image of the device, relevant data you can find in the data file. The name of the file contain device serial number, for example data_93130131_0.csv are from unit with number 93130131 (serial number is engraved on the top of the device)
Thermometers are placed from top in this order T3,T2,T1 (see picture in the software) Following is single sample line from file *data*.csv
0;31.10.2013 11:45;0;21.5625;22.0625;23.125;148;1;0
0 | index of the measure |
31.10.2013 11:45 | date and time in UTC |
0 | time zone |
21.5625 | T1 |
22.0625 | T2 |
23.125 | T3 |
148 | soil moisture count (raw moisture data) |
1 | shake |
0 | errFlag (if =1 the device couldn’t convert time from PCF chip) |
All measurement runs in UTC, please use time zone parameter for recalculation to the local time. There is shake sensor placed on the device, values can be only 1 (shake) or 0.